Mechanical
- Modeled and revised the enclosure in SolidWorks.
- Printed iterations to check component fit and assembly.
- Adjusted the casing as the electronics layout changed.
Wearable UV monitor.
Course prototypeSolBand brings a UV sensor, microcontroller, and display into a compact wearable prototype. I led prototyping and design, with hands-on work across the enclosure and hardware integration.

Our team was assigned to create something that could help people with a disability or disorder. We chose to focus on people with skin conditions that make them especially sensitive to sunlight.
I remembered friends experiencing painful sunburns and thought about how much more difficult sun exposure could be for someone with a sun-sensitive skin condition. We wanted to make UV exposure easier to recognize, giving users information they could use to make decisions about their time in the sun.
Working with four fellow engineering students, I helped brainstorm, design, prototype, and build SolBand: a functional UV-sensing wristband with a screen that displays UV readings and indicates when levels are harmful.
I led prototyping and design. My main responsibility was the casing, with additional work on component selection, soldering, microcontroller programming, and display integration.
I designed the casing in SolidWorks around the internal components. I revised the geometry, mounting features, and access points as the layout developed.
3D-printed versions let me check the physical fit and assembly. I used those checks to adjust the model before the next print.

Openings added to help heat escape from around the battery through passive ventilation.
An opening provides access to the USB-C charging connection used to recharge the device.
Narrow slots along the upper side walls were designed to hold the lid that encloses the internal components.
Internal indentations help position the components and organize their layout within the enclosure.
The curved base was designed to better follow the wrist's contour and improve how the case sits on the wristband.
Hover, focus, or tap a diamond to explore a feature. Select the image to enlarge it.
All prototype enclosures were printed in PLA as rough models to check whether the electronics would fit inside the case. These prints were used to evaluate component fit and develop the enclosure layout.
TPU was chosen for the final enclosure to provide flexibility with the wristband. The design goal was a case that could flex while remaining sturdy enough to support and help protect the internal electronics.
The circuit uses an Arduino Nano board, a UV sensor, an OLED display, and a rechargeable battery with a USB charging module. The controller reads the sensor and sends the readings to the display.
I contributed to part selection and soldering, as well as hardware integration and microcontroller programming. I helped select the components, solder their connections, and fit the electronics and wiring within the enclosure.
| Component | Summary |
|---|---|
| Arduino Nano | The microcontroller board and its connection pins. Runs the code that reads the UV sensor and updates the display. |
| UV sensor module | A UV-sensitive sensing element on a breakout board. Provides the light measurement used by the controller. |
| OLED display | A small display module that presents the sensor readings to the wearer. |
| LiPo battery | A rechargeable 3.7 V cell that supplies power to the wearable. |
| USB charging module | A USB input and charging circuit connected to the battery. |
We completed an MVP prototype with UV sensing, display output, and a physical enclosure. The project gave me experience coordinating mechanical design with electronics and revising a design through physical prototypes.
The course prototype established the basic system, but I see SolBand as a starting point for continued development. Even well-designed products have room to improve, and I hope to refine this device through repeated cycles of testing, feedback, and redesign.
My next priorities would be making it smaller, easier to assemble, and more useful to wear. The ideas below are proposed improvements that I would develop and test in another version.
Rework the internal layout to reduce unused space and improve the strap attachment. I would also refine the surfaces that contact the wrist and make the casing easier to open for assembly.
Printed fit checks would help compare comfort, component clearance, and access to the electronics before choosing the next enclosure.
Bring the prototype connections onto a compact PCB with planned locations for the sensor, display, and power connections. This would reduce loose wiring and make the electronics package easier to assemble consistently.
I would verify the circuit on the new board before redesigning the enclosure around its final dimensions.
Add a small vibration motor so the wearer can notice an alert without looking at the display. The firmware could trigger feedback when the UV reading passes a chosen threshold.
I would test whether the vibration is noticeable during normal activity and whether the display makes the meaning of each alert clear.
Measure the current draw of the controller, sensor, and display to understand where the battery power goes. Lower display brightness and sleep modes are options I would evaluate.
A runtime test under a defined usage pattern would show which changes actually help. I would also add a clear battery-status indication.
Compare the sensor readings with a reference UV meter across different light levels and device orientations. I would also check whether the enclosure opening or a protective cover changes the sensor response.
Those measurements would guide sensor placement and firmware adjustments, with repeatability checked after each revision.
Improve battery retention, wire strain relief, and the enclosure closure for repeated use. A gasketed lid and protected charging access are possibilities for a later revision.
I would evaluate the design through handling and controlled splash tests, while checking that the sensor and charging access remain usable.